Financing Special Offers Call Us Book Online

Ross Bolton

Ross Bolton

HVAC Service Manager

Rating

Reviews

Name: Ross Bolton

Certifications: NATE Certified - GA State Conditioned Air Contractor License #CN211241

Recent Jobs and Reviews

Rated 5.0 out of 5 stars based on 11 customer reviews

Customers say: Overall, the sentiment is overwhelmingly positive, reflecting a high level of satisfaction and trust in the company's service. Customers consistently praise the technicians' professionalism, punctuality, and friendly, personable manner, often noting that they arrived on time, respected the home, and left the work area clean. A recurring theme is clear, patient communication: technicians are described as explaining the problem, outlining options, and answering questions thoroughly, often with helpful demonstrations or visuals. Many reviewers emphasize the honesty and transparency of the service, appreciating the absence of pressure or unnecessary upselling and the sense that the technicians genuinely aim to solve the problem rather than inflate the bill. Quality, efficient workmanship, quick responsiveness to emergencies, and fair, competitive pricing are also widely mentioned, along with the convenience of repairs being completed in a single visit. The strong sense of relief, gratitude, and confidence expressed throughout, along with frequent mentions of repeat business and enthusiastic recommendations, points to a loyal customer base that views the company as a dependable, trustworthy go-to provider for plumbing and HVAC needs.

At a glance

True Plumbing, Heating & Cooling has completed 25 jobs between October 2026 and November 2026.

The 11 customer reviews shown here average 5.0 out of 5.

The most recent job was on November 13, 2026.

Recent work covers Atlanta, GA, Roswell, GA, Alpharetta, GA, Chamblee, GA and Dunwoody, GA.

Reviews

Great
Ross is very professional with a combination of experience and integrity which make him a strong leader to grow True's HVAC business.
Herbert - Atlanta, GA 30342
Great
Nice young man very professional
Mike - Atlanta, GA 30305
Great Service
This was a return visit following a holiday weekend purchase/installation of 2 hot water heaters installed by another employee of True Plumbing. Discovered there was no power to 1 of the new hot water heaters? Ross, their electrican came early Tuesday morning and discovered it was a breaker issue and resolved problem of why no hot water from 1 of the hot water heaters.
Pool girl - Atlanta, GA 30342
Great communications, needed service
Excellent. Answered questions and made things current
Roy - Roswell, GA 30076
Professional staff, quality work, fair price
Thoroughly professional staff. Competent, knowledgeable, courteous and hard working. Over 50+ years we have owned several homes and have worked with many contractors. Our experience with True ranks among the best.
Steve and Alberta - Roswell, GA 30076
Excellent service
Todd - Dunwoody, GA 30338
Excellent
It was great
Ashley - Atlanta, GA 30329
Exceptional Service
My AC went out overnight in the middle of a heat wave. I’ve used True for plumbing in the past and called them after the other HVAC company I had a service plan with wouldn’t come out to assess / repair for 6 days. (Hint - cancelling said service contract.) true came out same day. Fixed everything with a very thorough explanation of what needed to be done. They were already my go to for a plumbing and now they will be my only call for HVAC.
Amy - Alpharetta, GA 30022
Excellent Service
Ross was great! He was knowledgeable and polite. He took the time to show and explain to me what the problems were with our unit. We are very pleased!
Chris - Lawrenceville, GA 30044
Superior service
Ross was excellent…He diagnosed the issue promptly….made the repairs …and explained what he had done in plain English…
David - Johns Creek, GA 30022
Excellent service
Lori - Alpharetta, GA 30022

Job Locations

Ross B.
Ross B.
Responded to a no-heat call and performed a full diagnostic inspection of the furnace/air handler, including the blower compartment control board, low-voltage wiring, terminal connections, and fuse. Visual inspection found no frost, rust, or burn marks on the board, though the wiring was dense and tangled, and the adjacent gas water heater's gas connection and flue draft hood were also checked. Findings were reviewed with the customer and next-step recommendations were provided.
Roswell, GA 30076
Roswell, GA - Responded to a no-heat call and performed a full diagnostic inspection of the furnace/air handler, including the blower compartment control board, low-voltage wiring, terminal connections, and fuse. Visual inspection found no frost, rust, or burn marks on the board, though the wiring was dense and tangled, and the adjacent gas water heater's gas connection and flue draft hood were also checked. Findings were reviewed with the customer and next-step recommendations were provided.
Roswell, GA - Responded to a no-heat call and performed a full diagnostic inspection of the furnace/air handler, including the blower compartment control board, low-voltage wiring, terminal connections, and fuse. Visual inspection found no frost, rust, or burn marks on the board, though the wiring was dense and tangled, and the adjacent gas water heater's gas connection and flue draft hood were also checked. Findings were reviewed with the customer and next-step recommendations were provided.
Ross B.
Ross B.
Responded to a no-heat call on a dual-furnace attic installation, with separate Carrier and Payne gas furnaces serving the upstairs and downstairs zones. Removed the louvered access panel and front cabinet panel on the affected furnace to inspect the gas valve, burner assembly, wiring, and flue connections, and performed troubleshooting to diagnose the cause of the heating failure. Reinstalled all panels and secured the equipment after completing repairs.
Stone mountain, GA 30084
Stone mountain, GA - Responded to a no-heat call on a dual-furnace attic installation, with separate Carrier and Payne gas furnaces serving the upstairs and downstairs zones. Removed the louvered access panel and front cabinet panel on the affected furnace to inspect the gas valve, burner assembly, wiring, and flue connections, and performed troubleshooting to diagnose the cause of the heating failure. Reinstalled all panels and secured the equipment after completing repairs.
Stone mountain, GA - Responded to a no-heat call on a dual-furnace attic installation, with separate Carrier and Payne gas furnaces serving the upstairs and downstairs zones. Removed the louvered access panel and front cabinet panel on the affected furnace to inspect the gas valve, burner assembly, wiring, and flue connections, and performed troubleshooting to diagnose the cause of the heating failure. Reinstalled all panels and secured the equipment after completing repairs.
Ross B.
Ross B.
Performed fall maintenance inspection on gas furnace, including removal of the front access panel to inspect the burner assembly, control wiring, and flue connections. Noted corrosion and mineral buildup on the inducer motor housing and rust on the gas valve/manifold bolt head, and recommended monitoring these components for potential future repair or replacement.
Atlanta, GA 30324
Atlanta, GA - Performed fall maintenance inspection on gas furnace, including removal of the front access panel to inspect the burner assembly, control wiring, and flue connections. Noted corrosion and mineral buildup on the inducer motor housing and rust on the gas valve/manifold bolt head, and recommended monitoring these components for potential future repair or replacement.
Atlanta, GA - Performed fall maintenance inspection on gas furnace, including removal of the front access panel to inspect the burner assembly, control wiring, and flue connections. Noted corrosion and mineral buildup on the inducer motor housing and rust on the gas valve/manifold bolt head, and recommended monitoring these components for potential future repair or replacement.
Ross B.
Ross B.
Performed fall maintenance on the gas furnace and air handler system, including inspection of the electric heat section (8 kW/240V) and verification of wiring connections at the contactor and terminals, with no signs of damage, rust, or frost observed. Checked the furnace control board, internal wiring, condensate drainage and venting, gas line, and refrigerant line insulation, and confirmed the condensate pump and system components are in proper working order.
Doraville, GA 30360
Doraville, GA - Performed fall maintenance on the gas furnace and air handler system, including inspection of the electric heat section (8 kW/240V) and verification of wiring connections at the contactor and terminals, with no signs of damage, rust, or frost observed. Checked the furnace control board, internal wiring, condensate drainage and venting, gas line, and refrigerant line insulation, and confirmed the condensate pump and system components are in proper working order.
Doraville, GA - Performed fall maintenance on the gas furnace and air handler system, including inspection of the electric heat section (8 kW/240V) and verification of wiring connections at the contactor and terminals, with no signs of damage, rust, or frost observed. Checked the furnace control board, internal wiring, condensate drainage and venting, gas line, and refrigerant line insulation, and confirmed the condensate pump and system components are in proper working order.
Ross B.
Ross B.
Responded to a no-heat call on the upstairs attic-mounted gas furnace in a duplex, where the pilot would not remain lit and Atlanta Gas Light had shut off gas service to the unit. Inspected the furnace and gas valve assembly, documented the utility's shut-off tag and the equipment condition, and noted insulation debris and frost accumulation on the supply ductwork. Unit remains secured pending gas service restoration and repair of the pilot ignition fault.
Atlanta, GA 30306
Atlanta, GA - Responded to a no-heat call on the upstairs attic-mounted gas furnace in a duplex, where the pilot would not remain lit and Atlanta Gas Light had shut off gas service to the unit. Inspected the furnace and gas valve assembly, documented the utility's shut-off tag and the equipment condition, and noted insulation debris and frost accumulation on the supply ductwork. Unit remains secured pending gas service restoration and repair of the pilot ignition fault.
Atlanta, GA - Responded to a no-heat call on the upstairs attic-mounted gas furnace in a duplex, where the pilot would not remain lit and Atlanta Gas Light had shut off gas service to the unit. Inspected the furnace and gas valve assembly, documented the utility's shut-off tag and the equipment condition, and noted insulation debris and frost accumulation on the supply ductwork. Unit remains secured pending gas service restoration and repair of the pilot ignition fault.
Ross B.
Ross B.
Performed seasonal fall maintenance on the gas furnace, including removal of the front access panel to inspect the control board, wiring harnesses, relays, transformer, and burner assembly. Verified proper burner ignition and flame characteristics, and checked the flue venting, gas supply piping with flexible connectors and shutoff valves, and plenum/duct transition connections for integrity. Confirmed system is operating normally and ready for the heating season.
Atlanta, GA 30345
Atlanta, GA - Performed seasonal fall maintenance on the gas furnace, including removal of the front access panel to inspect the control board, wiring harnesses, relays, transformer, and burner assembly. Verified proper burner ignition and flame characteristics, and checked the flue venting, gas supply piping with flexible connectors and shutoff valves, and plenum/duct transition connections for integrity. Confirmed system is operating normally and ready for the heating season.
Ross B.
Ross B.
Responded to a fire inspection citation for exposed wiring at the rooftop condenser's electrical disconnect. Inspected the open disconnect enclosure and flexible conduit runs, then secured the conductors and installed the disconnect cover to eliminate exposed energized components. Verified conduit routing and enclosure integrity to restore code-compliant, safe operation of the unit.
Sandy Springs, GA 30328
Sandy Springs, GA - Responded to a fire inspection citation for exposed wiring at the rooftop condenser's electrical disconnect. Inspected the open disconnect enclosure and flexible conduit runs, then secured the conductors and installed the disconnect cover to eliminate exposed energized components. Verified conduit routing and enclosure integrity to restore code-compliant, safe operation of the unit.
Ross B.
Ross B.
Performed a pre-winter inspection of the upstairs heat pump system and the crawl space gas furnace and replaced the air filters. Inspected the Lennox air handler, noting dust accumulation on the blower wheel and cabinet insulation, aged foil-faced insulation, and brown staining on the blower housing. Checked electrical connections, control board wiring, and the contactor, confirmed the wire-nut splices and ground connection were secure, and verified the condensate PVC line was in place.
Decatur, GA 30033
Decatur, GA - Performed a pre-winter inspection of the upstairs heat pump system and the crawl space gas furnace and replaced the air filters. Inspected the Lennox air handler, noting dust accumulation on the blower wheel and cabinet insulation, aged foil-faced insulation, and brown staining on the blower housing. Checked electrical connections, control board wiring, and the contactor, confirmed the wire-nut splices and ground connection were secure, and verified the condensate PVC line was in place.
Decatur, GA - Performed a pre-winter inspection of the upstairs heat pump system and the crawl space gas furnace and replaced the air filters. Inspected the Lennox air handler, noting dust accumulation on the blower wheel and cabinet insulation, aged foil-faced insulation, and brown staining on the blower housing. Checked electrical connections, control board wiring, and the contactor, confirmed the wire-nut splices and ground connection were secure, and verified the condensate PVC line was in place.
Ross B.
Ross B.
Performed an on-site evaluation of the HVAC system in response to a heat exchanger replacement quote from another contractor. Inspected the exterior electrical disconnect, which was found to have debris and nesting material accumulated on the lid, and the interior utility closet housing the gas furnace/air handler, refrigerant lines, PVC condensate and vent piping, and supply ductwork, with no visible frost, rust, or cracks observed. Documented system conditions with photos to support a second-opinion assessment and recommendations.
Roswell, GA 30076
Roswell, GA - Performed an on-site evaluation of the HVAC system in response to a heat exchanger replacement quote from another contractor. Inspected the exterior electrical disconnect, which was found to have debris and nesting material accumulated on the lid, and the interior utility closet housing the gas furnace/air handler, refrigerant lines, PVC condensate and vent piping, and supply ductwork, with no visible frost, rust, or cracks observed. Documented system conditions with photos to support a second-opinion assessment and recommendations.
Roswell, GA - Performed an on-site evaluation of the HVAC system in response to a heat exchanger replacement quote from another contractor. Inspected the exterior electrical disconnect, which was found to have debris and nesting material accumulated on the lid, and the interior utility closet housing the gas furnace/air handler, refrigerant lines, PVC condensate and vent piping, and supply ductwork, with no visible frost, rust, or cracks observed. Documented system conditions with photos to support a second-opinion assessment and recommendations.
Ross B.
Ross B.
Replaced the upstairs air conditioning system and evaporator coil, including connection to the existing condensate drain and ductwork in the attic air handler. Replaced the main level filter drier to restore proper refrigerant circuit filtration, and reinsulated all accessible suction line insulation at the outdoor units to improve system efficiency and prevent condensation.
Roswell, GA 30076
Roswell, GA - Replaced the upstairs air conditioning system and evaporator coil, including connection to the existing condensate drain and ductwork in the attic air handler. Replaced the main level filter drier to restore proper refrigerant circuit filtration, and reinsulated all accessible suction line insulation at the outdoor units to improve system efficiency and prevent condensation.
Roswell, GA - Replaced the upstairs air conditioning system and evaporator coil, including connection to the existing condensate drain and ductwork in the attic air handler. Replaced the main level filter drier to restore proper refrigerant circuit filtration, and reinsulated all accessible suction line insulation at the outdoor units to improve system efficiency and prevent condensation.
Ross B.
Ross B.
Serviced the sunroom HVAC system, including the vertical air handler and outdoor condensing unit, using manifold gauges to diagnose and address refrigerant circuit performance. Inspected the supply ductwork, copper refrigerant lines, and condensate drain with pump to verify proper operation and drainage. System was tested and left operating as intended.
Dunwoody, GA 30338
Dunwoody, GA - Serviced the sunroom HVAC system, including the vertical air handler and outdoor condensing unit, using manifold gauges to diagnose and address refrigerant circuit performance. Inspected the supply ductwork, copper refrigerant lines, and condensate drain with pump to verify proper operation and drainage. System was tested and left operating as intended.
Dunwoody, GA - Serviced the sunroom HVAC system, including the vertical air handler and outdoor condensing unit, using manifold gauges to diagnose and address refrigerant circuit performance. Inspected the supply ductwork, copper refrigerant lines, and condensate drain with pump to verify proper operation and drainage. System was tested and left operating as intended.
Ross B.
Ross B.
Performed fall maintenance inspection on the furnace/air handler, documenting corrosion on the gas piping nipple and fitting at the cabinet penetration, along with rust staining on the cabinet panel and evaporator coil casing. Noted torn and peeling foil-faced insulation near the coil assembly and confirmed the 3/4" PVC condensate drain line was properly routed and intact. Recommend further evaluation of the corroded gas fitting and repair of the damaged insulation to prevent continued deterioration.
Atlanta, GA 30305
Atlanta, GA - Performed fall maintenance inspection on the furnace/air handler, documenting corrosion on the gas piping nipple and fitting at the cabinet penetration, along with rust staining on the cabinet panel and evaporator coil casing. Noted torn and peeling foil-faced insulation near the coil assembly and confirmed the 3/4" PVC condensate drain line was properly routed and intact. Recommend further evaluation of the corroded gas fitting and repair of the damaged insulation to prevent continued deterioration.
Atlanta, GA - Performed fall maintenance inspection on the furnace/air handler, documenting corrosion on the gas piping nipple and fitting at the cabinet penetration, along with rust staining on the cabinet panel and evaporator coil casing. Noted torn and peeling foil-faced insulation near the coil assembly and confirmed the 3/4" PVC condensate drain line was properly routed and intact. Recommend further evaluation of the corroded gas fitting and repair of the damaged insulation to prevent continued deterioration.
Ross B.
Ross B.
Performed a pre-season inspection of the gas furnace prior to heating-season startup. With the upper access panel removed, verified the burner assembly produced a stable blue flame and inspected the draft inducer motor, gas valve and piping, pressure switch, and wiring for proper condition. Confirmed the vintage Honeywell Chronotherm thermostat is intact with no visible damage, and the system was left operating normally.
Atlanta, GA 30328
Atlanta, GA - Performed a pre-season inspection of the gas furnace prior to heating-season startup. With the upper access panel removed, verified the burner assembly produced a stable blue flame and inspected the draft inducer motor, gas valve and piping, pressure switch, and wiring for proper condition. Confirmed the vintage Honeywell Chronotherm thermostat is intact with no visible damage, and the system was left operating normally.
Atlanta, GA - Performed a pre-season inspection of the gas furnace prior to heating-season startup. With the upper access panel removed, verified the burner assembly produced a stable blue flame and inspected the draft inducer motor, gas valve and piping, pressure switch, and wiring for proper condition. Confirmed the vintage Honeywell Chronotherm thermostat is intact with no visible damage, and the system was left operating normally.
Ross B.
Ross B.
Performed seasonal fall maintenance on the gas furnace and air handler, inspecting the blower compartment, motor, wiring, and control board for proper operation and signs of wear. Checked the condensate drain line and PVC piping for secure connections and unobstructed flow, and verified the refrigerant line insulation and supply ductwork were intact. Inspected the gas water heater's flue connection, vent piping, and expansion tank, and confirmed no visible frost, rust, or leaks, leaving the system ready for heating season.
Roswell, GA 30076
Roswell, GA - Performed seasonal fall maintenance on the gas furnace and air handler, inspecting the blower compartment, motor, wiring, and control board for proper operation and signs of wear. Checked the condensate drain line and PVC piping for secure connections and unobstructed flow, and verified the refrigerant line insulation and supply ductwork were intact. Inspected the gas water heater's flue connection, vent piping, and expansion tank, and confirmed no visible frost, rust, or leaks, leaving the system ready for heating season.
Roswell, GA - Performed seasonal fall maintenance on the gas furnace and air handler, inspecting the blower compartment, motor, wiring, and control board for proper operation and signs of wear. Checked the condensate drain line and PVC piping for secure connections and unobstructed flow, and verified the refrigerant line insulation and supply ductwork were intact. Inspected the gas water heater's flue connection, vent piping, and expansion tank, and confirmed no visible frost, rust, or leaks, leaving the system ready for heating season.
Ross B.
Ross B.
Performed inspection of HVAC units and completed product registration for the Rheem unit. Inspected the control enclosure and visually verified circuit boards, wiring harnesses, plug-in connectors, and protective grommets to be properly seated and free of damage, corrosion, or rust. Examined the damper actuator assembly and surrounding foam insulation and foil tape seals, finding all components intact with no visible deficiencies.
Roswell, GA 30076
Roswell, GA - Performed inspection of HVAC units and completed product registration for the Rheem unit. Inspected the control enclosure and visually verified circuit boards, wiring harnesses, plug-in connectors, and protective grommets to be properly seated and free of damage, corrosion, or rust. Examined the damper actuator assembly and surrounding foam insulation and foil tape seals, finding all components intact with no visible deficiencies.
Roswell, GA - Performed inspection of HVAC units and completed product registration for the Rheem unit. Inspected the control enclosure and visually verified circuit boards, wiring harnesses, plug-in connectors, and protective grommets to be properly seated and free of damage, corrosion, or rust. Examined the damper actuator assembly and surrounding foam insulation and foil tape seals, finding all components intact with no visible deficiencies.
Ross B.
Ross B.
Performed an on-site estimate and visual assessment of the HVAC system for a prospective maintenance customer considering a switch from their current provider. Inspected a Lennox gas furnace with attached condensate pump, refrigerant line set, galvanized flue, and foil-faced supply plenum, along with three exterior air conditioning condensers on a gravel pad with disconnect and conduit; all components appeared intact with no visible rust, frost, or damage. Documented equipment with photos to support a maintenance proposal.
Atlanta, GA 30342
Atlanta, GA - Performed an on-site estimate and visual assessment of the HVAC system for a prospective maintenance customer considering a switch from their current provider. Inspected a Lennox gas furnace with attached condensate pump, refrigerant line set, galvanized flue, and foil-faced supply plenum, along with three exterior air conditioning condensers on a gravel pad with disconnect and conduit; all components appeared intact with no visible rust, frost, or damage. Documented equipment with photos to support a maintenance proposal.
Atlanta, GA - Performed an on-site estimate and visual assessment of the HVAC system for a prospective maintenance customer considering a switch from their current provider. Inspected a Lennox gas furnace with attached condensate pump, refrigerant line set, galvanized flue, and foil-faced supply plenum, along with three exterior air conditioning condensers on a gravel pad with disconnect and conduit; all components appeared intact with no visible rust, frost, or damage. Documented equipment with photos to support a maintenance proposal.
Ross B.
Ross B.
Inspected the upper-floor air handler after the secondary drain pan was found full of water and identified evidence of a condensate drain restriction, with heavy rust and corrosion on the cabinet floor and mineral staining at the base seam near the PVC drain connection. Recommended clearing and flushing the primary condensate line, draining the pan, and treating or replacing the corroded components to prevent overflow and water damage to the structure.
Roswell, GA 30076
Roswell, GA - Inspected the upper-floor air handler after the secondary drain pan was found full of water and identified evidence of a condensate drain restriction, with heavy rust and corrosion on the cabinet floor and mineral staining at the base seam near the PVC drain connection. Recommended clearing and flushing the primary condensate line, draining the pan, and treating or replacing the corroded components to prevent overflow and water damage to the structure.
Roswell, GA - Inspected the upper-floor air handler after the secondary drain pan was found full of water and identified evidence of a condensate drain restriction, with heavy rust and corrosion on the cabinet floor and mineral staining at the base seam near the PVC drain connection. Recommended clearing and flushing the primary condensate line, draining the pan, and treating or replacing the corroded components to prevent overflow and water damage to the structure.
Ross B.
Ross B.
Responded to a no-heat/no-cool call after a failed customer thermostat replacement. Inspected the Goodman gas furnace and the control wiring, then reviewed the electrical panel to confirm the HVAC circuits (including the two AC breakers) are properly identified. Estimate prepared for reinstalling the thermostat, verifying low-voltage wire connections, and testing furnace and air conditioning operation.
Tucker, GA 30084
Tucker, GA - Responded to a no-heat/no-cool call after a failed customer thermostat replacement. Inspected the Goodman gas furnace and the control wiring, then reviewed the electrical panel to confirm the HVAC circuits (including the two AC breakers) are properly identified. Estimate prepared for reinstalling the thermostat, verifying low-voltage wire connections, and testing furnace and air conditioning operation.
Tucker, GA - Responded to a no-heat/no-cool call after a failed customer thermostat replacement. Inspected the Goodman gas furnace and the control wiring, then reviewed the electrical panel to confirm the HVAC circuits (including the two AC breakers) are properly identified. Estimate prepared for reinstalling the thermostat, verifying low-voltage wire connections, and testing furnace and air conditioning operation.
Ross B.
Ross B.
Responded to a no-heat call on a Trane XR80 gas furnace and diagnosed failed draft inducer motor and pressure switch components. Removed the faulty inducer motor and pressure switch, installed new replacements, and reconnected the wire harness and connectors. Verified secure connections and proper inducer operation to restore the heating cycle.
Chamblee, GA 30341
Chamblee, GA - Responded to a no-heat call on a Trane XR80 gas furnace and diagnosed failed draft inducer motor and pressure switch components. Removed the faulty inducer motor and pressure switch, installed new replacements, and reconnected the wire harness and connectors. Verified secure connections and proper inducer operation to restore the heating cycle.
Chamblee, GA - Responded to a no-heat call on a Trane XR80 gas furnace and diagnosed failed draft inducer motor and pressure switch components. Removed the faulty inducer motor and pressure switch, installed new replacements, and reconnected the wire harness and connectors. Verified secure connections and proper inducer operation to restore the heating cycle.
Ross B.
Ross B.
Installed a whole-home dehumidifier in the mechanical room and connected it to the existing duct system using a flexible duct collar. Wrapped the supply ductwork in foil-faced insulation to reduce condensation and heat transfer, and verified that all connections were secure and the installation was clean and free of damage.
Atlanta, GA 30319
Atlanta, GA - Installed a whole-home dehumidifier in the mechanical room and connected it to the existing duct system using a flexible duct collar. Wrapped the supply ductwork in foil-faced insulation to reduce condensation and heat transfer, and verified that all connections were secure and the installation was clean and free of damage.
Atlanta, GA - Installed a whole-home dehumidifier in the mechanical room and connected it to the existing duct system using a flexible duct collar. Wrapped the supply ductwork in foil-faced insulation to reduce condensation and heat transfer, and verified that all connections were secure and the installation was clean and free of damage.
Ross B.
Ross B.
Responded to a no heat complaint with intermittent operation on the heat pump system serving the laundry room air handler. Inspected the outdoor condensing units and found the equipment intact with no frost, ice, or corrosion, but with heavy accumulation of pine needles, leaves, and debris around the service valves, refrigerant line fittings, and base of the unit. Documented the unit condition and nameplate data, and diagnosed the intermittent cycling to continue troubleshooting.
Norcross, GA 30092
Norcross, GA - Responded to a no heat complaint with intermittent operation on the heat pump system serving the laundry room air handler. Inspected the outdoor condensing units and found the equipment intact with no frost, ice, or corrosion, but with heavy accumulation of pine needles, leaves, and debris around the service valves, refrigerant line fittings, and base of the unit. Documented the unit condition and nameplate data, and diagnosed the intermittent cycling to continue troubleshooting.
Norcross, GA - Responded to a no heat complaint with intermittent operation on the heat pump system serving the laundry room air handler. Inspected the outdoor condensing units and found the equipment intact with no frost, ice, or corrosion, but with heavy accumulation of pine needles, leaves, and debris around the service valves, refrigerant line fittings, and base of the unit. Documented the unit condition and nameplate data, and diagnosed the intermittent cycling to continue troubleshooting.
Ross B.
Ross B.
Responded to a no-heat call on a crawlspace-installed gas furnace and performed a full system inspection, including the control board, wiring, gas valve, inducer assembly, and filter, noting heavy soot, scorching, and disorganized wiring throughout the cabinet. Corrected the fault preventing the furnace from starting, restored heat, and verified proper ignition and operation through a complete heating cycle. Recommended cleaning, wiring cleanup, and further evaluation of the scorched areas and corroded components to prevent future failures.
Chamblee, GA 30341
Chamblee, GA - Responded to a no-heat call on a crawlspace-installed gas furnace and performed a full system inspection, including the control board, wiring, gas valve, inducer assembly, and filter, noting heavy soot, scorching, and disorganized wiring throughout the cabinet. Corrected the fault preventing the furnace from starting, restored heat, and verified proper ignition and operation through a complete heating cycle. Recommended cleaning, wiring cleanup, and further evaluation of the scorched areas and corroded components to prevent future failures.
Chamblee, GA - Responded to a no-heat call on a crawlspace-installed gas furnace and performed a full system inspection, including the control board, wiring, gas valve, inducer assembly, and filter, noting heavy soot, scorching, and disorganized wiring throughout the cabinet. Corrected the fault preventing the furnace from starting, restored heat, and verified proper ignition and operation through a complete heating cycle. Recommended cleaning, wiring cleanup, and further evaluation of the scorched areas and corroded components to prevent future failures.
Ross B.
Ross B.
Replaced the existing gas control valve on the gas-fired furnace, disconnecting the gas supply and electrical terminal connections and installing the new valve with secure threaded fittings. Reconnected the wiring to the valve terminals, restored gas and power, and leak-tested all gas connections to confirm proper operation. Noted heavy rust and corrosion on the burner compartment panels and gas supply piping, along with dust and soot buildup on the burner assembly, which should be monitored and addressed as part of future maintenance.
Atlanta, GA 30350
Atlanta, GA - Replaced the existing gas control valve on the gas-fired furnace, disconnecting the gas supply and electrical terminal connections and installing the new valve with secure threaded fittings. Reconnected the wiring to the valve terminals, restored gas and power, and leak-tested all gas connections to confirm proper operation. Noted heavy rust and corrosion on the burner compartment panels and gas supply piping, along with dust and soot buildup on the burner assembly, which should be monitored and addressed as part of future maintenance.
Atlanta, GA - Replaced the existing gas control valve on the gas-fired furnace, disconnecting the gas supply and electrical terminal connections and installing the new valve with secure threaded fittings. Reconnected the wiring to the valve terminals, restored gas and power, and leak-tested all gas connections to confirm proper operation. Noted heavy rust and corrosion on the burner compartment panels and gas supply piping, along with dust and soot buildup on the burner assembly, which should be monitored and addressed as part of future maintenance.
Ross B.
Ross B.
Performed seasonal winterization and general maintenance on the HVAC system, including inspection of both outdoor condenser units, refrigerant line insulation, electrical disconnect and conduit connections, and clearing of leaf debris and mulch from around the units. Inspected attic air handling components, including insulated flex ductwork, condensate drain piping, and surrounding blown-in insulation, to verify proper condition and system readiness for cold-weather operation.
Atlanta, GA 30319
Atlanta, GA - Performed seasonal winterization and general maintenance on the HVAC system, including inspection of both outdoor condenser units, refrigerant line insulation, electrical disconnect and conduit connections, and clearing of leaf debris and mulch from around the units. Inspected attic air handling components, including insulated flex ductwork, condensate drain piping, and surrounding blown-in insulation, to verify proper condition and system readiness for cold-weather operation.
Atlanta, GA - Performed seasonal winterization and general maintenance on the HVAC system, including inspection of both outdoor condenser units, refrigerant line insulation, electrical disconnect and conduit connections, and clearing of leaf debris and mulch from around the units. Inspected attic air handling components, including insulated flex ductwork, condensate drain piping, and surrounding blown-in insulation, to verify proper condition and system readiness for cold-weather operation.
Ross B.
Ross B.
Fabricated and installed a new return air plenum on the attic-mounted Goodman gas furnace/air handler, sealing all connections and wrapping with foil-faced insulation to restore proper return airflow. Repaired damaged sections of flexible ductwork, re-securing and re-insulating the affected runs to ensure airtight, efficient air distribution.
Cumming, GA 30041
Cumming, GA - Fabricated and installed a new return air plenum on the attic-mounted Goodman gas furnace/air handler, sealing all connections and wrapping with foil-faced insulation to restore proper return airflow. Repaired damaged sections of flexible ductwork, re-securing and re-insulating the affected runs to ensure airtight, efficient air distribution.
Cumming, GA - Fabricated and installed a new return air plenum on the attic-mounted Goodman gas furnace/air handler, sealing all connections and wrapping with foil-faced insulation to restore proper return airflow. Repaired damaged sections of flexible ductwork, re-securing and re-insulating the affected runs to ensure airtight, efficient air distribution.
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 404-585-8990 .

By pressing Submit I agree to receive phone, email, or text messages from True Plumbing, Heating & Cooling to the provided mobile number and also agree to the True Plumbing, Heating & Cooling terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next